BR-CL-10 EN 16931 Math & Tax EU FATAL REJECTION
BR-CL-10 — Invalid ISO 6523 ICD, CEF EAS, or UN/ECE Rec 20 Code List Value
Rule Definition & Compliance Impact
The BR-CL rule family validates controlled code attributes across EN 16931: ISO 6523 ICD schemeIDs on legal/party IDs (BR-CL-10/11), CEF EAS schemeIDs on electronic addresses BT-34/BT-49 (BR-CL-25), and UN/ECE Recommendation 20/21 unitCode values on quantities (BR-CL-23).
Common ERP & Exporter Root Causes
Developers write human labels like unitCode='PCS', unitCode='BUC', unitCode='STÜCK', schemeID='SIREN', or schemeID='EMAIL' instead of normative registry codes.
How to Fix This Violation
Map local units and schemes to official codes: use C62 (unit), H87 (piece), HUR (hour), DAY (day), KGM (kilogram) for unitCode; '0002' for French SIREN, '0009' for SIRET, '0088' for GLN, and 'EM' for email Electronic Address Scheme.
Non-Compliant vs. Compliant Payload Comparison
UN/CEFACT CII D16B (Factur-X / ZUGFeRD)
REJECTED
<ram:BilledQuantity unitCode="PCS">5</ram:BilledQuantity>
<!-- 'PCS' is not a valid UN/ECE Recommendation 20 code; schemeID 'SIREN' is not ISO 6523! --> COMPLIANT
<ram:BilledQuantity unitCode="H87">5</ram:BilledQuantity>
<!-- H87 = Piece, C62 = One/Unit, HUR = Hour, DAY = Day; ISO 6523 '0002' = French SIREN -->OASIS UBL 2.1 (XRechnung / Peppol / RO e-Factura)
REJECTED
<cbc:EndpointID schemeID="EMAIL">[email protected]</cbc:EndpointID>
<cbc:InvoicedQuantity unitCode="BUC">5</cbc:InvoicedQuantity> COMPLIANT
<cbc:EndpointID schemeID="EM">[email protected]</cbc:EndpointID>
<cbc:InvoicedQuantity unitCode="H87">5</cbc:InvoicedQuantity>